Peak Power Sensors

asthma rescue inhaler dosage

otc asthma inhaler cvs

sertraline and alcohol uk

sertraline and alcohol side effects go

 

Model

Frequency Range

Dynamic Range

Overload Rating

Sensor Response

Maximum SWR

Impedance
Connector
(Low Bandwidth) Peak Pwr Rng
CW Pwr Rng
Int. Trigger Range
Pulse/Continuous Fast Risetime (Bandwidth) Slow Risetime (Bandwidth) Frequency SWR @ 0 dBm
For use with models 4500B and 4540.

57006

50 ohm
N (M)
0.5 - 6 GHz
(0.05 - 6 GHz)
-50 to +20 dBm
-60 to +20 dBm
-40 to +20 dBm
1 W for 1µs
200 mW
<7 ns
(70 MHz typical)
<10 µs
(350 kHz)
0.05 - 6 GHz
 
1.25

59318

50 ohm
N (M)
0.5 - 18 GHz
(0.05 - 18 GHz)
-24 to +20 dBm
-34 to +20 dBm
-10 to +20 dBm
1 W for 1µs
200 mW
<10 ns
(50 MHz typical)
<10 µs
(350 kHz)
0.05 - 2 GHz
2 - 16 GHz
16 - 18 GHz
1.15
1.28
1.34

59340

50 ohm
K (M)
0.5 - 40 GHz
(0.05 - 40 GHz)
-24 to +20 dBm
-34 to +20 dBm
-10 to +20 dBm
1 W for 1µs
200 mW
<10 ns
(50 MHz typical)
<10 µs
(350 kHz)
0.05 - 4 GHz
4 - 38 GHz
38 - 40 GHz
1.25
1.65
2.00
For use with models 4400, 4500, 4400A, and 4500A analyzers. Model 4530 w/1 GHz calibrator Model 2530.

56318

50 ohm
N (M)
0.5 - 18 GHz -24 to +20 dBm
-34 to +20 dBm
-10 to +20 dBm
1 W for 1µs
200 mW
<15 ns
(35 MHz)
<200 ns
(1.75 MHz)
0.5 - 2 GHz
2 - 16 GHz
16 - 18 GHz
1.15
1.28
1.34

56326

50 ohm
K (M)
0.5 - 26.5 GHz -24 to +20 dBm
-34 to +20 dBm
-10 to +20 dBm
1 W for 1µs
200 mW
<15 ns
(35 MHz)
<200 ns
(1.75 MHz)
0.5 - 2 GHz
2 - 4 GHz
4 - 18 GHz
18 - 26.5 GHz
1.15
1.20
1.45
1.50

56518

50 ohm
N (M)
0.5 - 18 GHz -40 to +20 dBm
-50 to +20 dBm
-27 to +20 dBm
1 W for 1µs
200 mW
<100 ns
(6 MHz)
<300 ns
(1.16 MHz)
0.5 - 2 GHz
2 - 6 GHz
6 - 16 GHz
16 - 18 GHz
1.15
1.20
1.28
1.34
For use with models 4400, 4500, 4400A, 4500A and 4530.

57518

50 ohm
N (M)
0.1 - 18 GHz
(0.05 - 18 GHz)
-40 to +20 dBm
-50 to +20 dBm
-27 to +20 dBm
1 W for 1µs
200 mW
<100 ns
(6 MHz)
<10 µs
(350 kHz)
0.05 - 2 GHz
2 - 16 GHz
16 - 18 GHz
1.15
1.28
1.34

57540

50 ohm
K (M)
0.1 - 40 GHz
(0.05 - 40 GHz)
-40 to +20 dBm
-50 to +20 dBm
-27 to +20 dBm
1 W for 1µs
200 mW
<100 ns
(6 MHz)
<10 µs
(350 kHz)
0.05 - 4 GHz
4 - 38 GHz
38 - 40 GHz
1.25
1.65
2.00
For use with 4500, 4400, and 4530

56218

50 ohm
N (M)
30 MHz - 18 GHz -24 to +20 dBm
-34 to +20 dBm
-10 to +20 dBm
1 W for 1µs
200 mW
<150 ns
(3 MHz)
<500 µs
(700 kHz)
0.03 - 2 GHz
2 - 6 GHz
6 - 18 GHz
1.15
1.20
1.25
For use with 4500 and 4400

56526

50 ohm
K (M)
500 MHz - 26.5 GHz -40 to +20 dBm
-50 to +20 dBm
-27 to +20 dBm
1 W for 1µs
200 mW
<100 ns
(6 MHz)
<300 µs
(1.16 MHz)
0.03 - 2 GHz
2 - 6 GHz
4 - 18 GHz
18 - 26.5 GHz
1.15
1.20
1.45
1.50

 


 

Bize Ulaşın
(0212) 220 34 83
info@egerate.com